FEATURES,
SPECIFICATIONS
AND BENEFITS |
 |
 We install Model 81 |
-
 We install Model 81
|
| APPLICATION |
Drum-type
humidifier with capacity for most homes. Installs on vertical warm air
supply or cold air return (recommended) plenum. |
Drum-type
humidifier designed for condominiums, town homes and smaller houses. Installs
on vertical warm air supply or cold air return (recommended) plenum. |
Perfect
choice when plenum mount is not possible. Drum-type humidifier mounts
in any 16" wide horizontal warm air duct. (May be installed in 12"
duct; output reduced.) |
| UNIT
SIZE |
12"
wide x 11-1/2" high x 11" deep |
10"
wide x 9" high x 9-1/2" deep |
12"
wide x 16" high x 4" deep |
| PLENUM
OPENING |
8"
wide x 7-1/2" high |
7-3/4"
wide x 5-3/4" high |
10-1/2"
wide x 15-1/8" high |
| BYPASS
DUCT |
6"
diameter (Bypass Pipe Assembly Supplied) |
5"
diameter (Bypass Pipe Assembly Supplied) |
N/A |
EVAPORATIVE
OUTPUT CAPACITY @ .20"
PRESSURE DIFFERENTIAL
(except 747 rated at 800 FPM duct velocity)
ABOVE AT STANDARD INDUSTRY RATING CONDITIONS |
|
Temp
°F
|
GPD
|
|
80°
|
7.0
|
|
100°
|
11.3
|
|
120°
|
16.0
|
|
140°
|
18.0
|
|
160°
|
21.7
|
|
|
Temp
°F
|
GPD
|
|
80°
|
6.2
|
|
100°
|
8.5
|
|
120°
|
10.9
|
|
140°
|
13.3
|
|
160°
|
15.7
|
|
|
Temp
°F
|
GPD
|
|
80°
|
4.1
|
|
100°
|
8.7
|
|
120°
|
12.8
|
|
140°
|
16.0
|
|
160°
|
19.2
|
*@
800 FPM duct velocity |
| EVAPORATIVE
PRINCIPLE GENERALAire humidifers are 100% evaporative, adding moisture
in the form of water vapor only. They are clean operating. The nuisance
of airborne water droplets or mineral dust is avoided. |
Forced
warm air heating systems create a pressure differential that diverts some
heated air through a bypass duct to the humidifier. There, the warm air
absorbs moisture from a water-soaked, drum-mounted evaporator sleeve and
then rejoins the primary warm air stream for distribution throughout the
living area. The drum-mounted evaporator sleeve picks up moisture as it
slowly rotates in a water reservoir. A float valve controls the level
of water in the reservoir. |
Forced
warm air heating systems create a pressure differential that diverts some
heated air through a bypass duct to the humidifier. There, the warm air
absorbs moisture from a water-soaked, drum-mounted evaporator sleeve and
then rejoins the primary warm air stream for distribution throughout the
living area. The drum-mounted evaporator sleeve picks up moisture as it
slowly rotates in a water reservoir. A float valve controls the level
of water in the reservoir. |
Heated
air in the system duct absorbs moisture as it passes across and through
a water-soaked, drum-mounted evaporator sleeve on its way to the living
area. The drum-mounted evaporator sleeve picks up moisture as it slowly
rotates in a water reservoir. A float valve controls the level of water
in the reservoir. |
| EVAPORATIVE
MEDIA |
81-15
Evaporator sleeve. Split drum allows easy separation for removal of polyurethane
foam sleeve for cleaning. |
65-5
Evaporator sleeve. Split drum allows easy separation for removal of polyurethane
foam sleeve for cleaning. |
727-12
Evaporator sleeve. Split drum allows easy separation for removal of polyurethane
foam sleeve for cleaning. |
| WATER
SUPPLY |
Unique,
time-proven GENERALAire float valve assembly meters water into reservoir
through precision machined orifice. Saddle valve and 1/4" plastic
tubing included. |
Unique,
time-proven GENERALAire float valve assembly meters water into reservoir
through precision machined orifice. Saddle valve and 1/4" plastic
tubing included. |
Unique,
time-proven GENERALAire float valve assembly meters water into reservoir
through precision machined orifice. Saddle valve and 1/4" plastic
tubing included. |
| DRAIN
CONNECTION |
N/A |
N/A |
Unique
quick drain device permits easy draining to reduce mineral
concentrations. |
| RANGE
OF MODELS |
N/A |
N/A |
N/A |
| ELECTRICAL |
24
V., .03 Amp, 60 Hz. (Transformer and hook-up wire supplied) |
24
V., .03 Amp, 60 Hz. (Transformer and hook-up wire supplied) |
24
V., .03 Amp, 60 Hz. (Transformer and hook-up wire supplied) |
| CONTROLS |
Manual
air shutter for summer shut-off. Includes GENERALAire H-86 wall/duct mount
humidistat. |
Manual
air shutter for summer shut-off. Includes GENERALAire H-86 wall/duct mount
humidistat. |
Manual
control uses built-in thermostat to sense duct temperature and activate/deactivate
unit to adjust output. Automatic humidistat is optional. |
CONSTRUCTION,
MATERIALS AND STYLING |
Modern
cabinet molded of high temperature polymer. Sturdy gear motor and one-piece,
corrosion proof reservoir for long service life. |
Modern
cabinet molded of high temperature polymer. Sturdy gear motor and one-piece,
corrosion proof reservoir for long service life. |
Sturdy
gear motor and one-piece, corrosion proof reservoir for long service life. |
| VERSATILITY |
Unique
design allows right or left hand installation by reversing drum and repositioning
float valve, drive motor and bypass. May be installed on up-flow, counter-flow
or horizontal furnaces or air handlers. |
Unique
design allows right or left hand installation by reversing drum and repositioning
float valve, drive motor and bypass. May be installed on up-flow, counter-flow
or horizontal furnaces or air handlers. |
Mounts
in ducts 16" or larger with evaporator sleeve perpendicular to air
flow (preferred, for highest output) or in line to air flow in ducts 14"
or smaller (for reduced output). |
| SERVICEABILITY |
Thumbscrews
release removable front cover. Water tray slides out for easy cleaning.
|
Thumbscrews
release removable front cover. Water tray slides out for easy cleaning. |
Quick
drain device empties reservoir prior to servicing. Unique built-in
hinge allows unit to swing down for easy access. |
| EASY
INSTALLATION GENERALAire humidifers are specially designed for
fast, easy installation |
Fully
assembled with most important installation components included. |
Fully
assembled with most important installation components included. |
Unique
mounting bracket and most important installation components included. |